Innovative Methodology
Integrative and Computational Neuroscience Unit (UNIC), Centre National de la Recherche Scientifique, 91198 Gif-sur-Yvette, France
Submitted 17 December 2003; accepted in final form 1 February 2004
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
15 mV depolarized with respect to rest), a 3- to 5-fold diminished input resistance, and high-amplitude Vm fluctuations (SD of the Vm of about
v = 4 mV).
Several types of computational models have been proposed to investigate high-conductance states. Biophysically detailed computational models can integrate the dendritic morphology of cortical neurons, and simulate active channels in soma and dendrites, as well as the large number of excitatory and inhibitory synapses underlying background activity (Bernander et al. 1991
; Destexhe and Paré 1999
; Rudolph and Destexhe 2003a
). On the other hand, simplified models consider single compartments ("point-neurons") with global excitatory and inhibitory conductances (Destexhe et al. 2001
). In this case, each global conductance represents the sum of a large number of individual synaptic inputs and is modeled by stochastic processes. The advantage of the latter approach is that the stochastic variations of synaptic conductances can be injected in real neurons to re-create high-conductance states in vitro, as shown in a number of recent studies (Chance et al. 2002
; Destexhe et al. 2001
; Fellous et al. 2003
; Prescott and De Koninck 2003
; Shu et al. 2003b
) using the dynamic-clamp technique (Robinson and Kawai 1993
; Sharp et al. 1993
). These computational and dynamic-clamp approaches have shown that high-conductance states have a number of computational consequences on cortical neurons (reviewed in Destexhe et al. 2003
). The stochastic and intense synaptic activity enhances their responsiveness (Hô and Destexhe 2000
), modulates their gain (Chance et al. 2002
; Fellous et al. 2003
; Shu et al. 2003), sharpens the temporal processing of inputs (Bernander et al. 1991
; Shelley et al. 2002
; Shu et al. 2003b
), or equalizes synaptic efficacies (Rudolph and Destexhe 2003a
).
Another consequence of high-conductance states is that the subthreshold activity of any single neocortical neuron contains a large amount of information about the rest of the network. This is attributed to the particularly high level of firing activity of cortical neurons (see above), together with the dense intracortical connectivity (5,000 to 60,000 excitatory synapses per neuron; see DeFelipe and Fariñas 1992
). Thus, neocortical neurons should provide a good "sampling" of the activity of a large number of neurons in the network, as indeed shown by the tight correlation between EEG and intracellular activity in cortex (Contreras and Steriade 1995
; Creutzfeldt et al. 1996a,b; Klee et al. 1965
). In principle it should be possible to deduce properties of network activity by analyzing the subthreshold dynamics of the Vm, but unfortunately no such methods are yet available. The main difficulty is to relate collective properties at the network level into identifiable patterns of synaptic activity. At present, only global characterizations are possible, such as for example characterizing the mean rate of firing of the excitatory and inhibitory cells, which should translate into the mean value of global excitatory and inhibitory conductances. Interestingly, the variance of global synaptic conductances is related to the average amount of correlation present among presynaptic neurons (Destexhe et al. 2001
), but it is presently very difficult to estimate the variance of conductances.
A possible path toward such a characterization is to obtain a good mathematical description of the dynamics of synaptic noise, and deduce useful relations between the Vm dynamics and presynaptic activity. However, the mathematical description must not be too complex, to allow inverting the relations and obtain characteristics of network activity as a function of Vm measurements. This is the approach that we follow in this paper. We showed that by using stochastic calculus, one can obtain an analytical description of the steady-state Vm distribution (Rudolph and Destexhe 2003b
). We use here the results of this theoretical approach to analyze the Vm activity of cortical neurons. The method of analysis we propose is tested against computational models of increasing complexity, as well as in real neurons during active states in vitro. Part of these results have appeared in 2 conference abstracts (Destexhe et al. 2003
; Rudolph and Destexhe 2002
).
| METHODS |
|---|
|
|
|---|
To reproduce the stochastic membrane potential fluctuations and high-conductance state characterizing the dynamics of neocortical neurons in vivo, several types of neuronal models were used and compared (see Fig. 1).
|
The first model was a point-conductance model (Destexhe et al. 2001
), which consisted in a single-compartment neuron described by the passive stochastic membrane equation
![]() | (1) |
![]() | (2) |
![]() | (3) |
e and
i are time constants,
e and
i are noise SD values, and
e(t) and
i(t) denote independent Gaussian white noise processes of unit SD and zero mean.
The model was accessed both analytically and numerically. In the latter case, the membrane area of the compartment was a = 34,636 µm2 (corresponding to the layer VI neocortical pyramidal cells from cat parietal cortex used in Destexhe et al. 2001
), and passive parameters were gL = 0.0452 mS/cm2, EL = -80 mV, Cm = 1 µF/cm2 (Destexhe and Paré 1999
; Paré et al. 1998
), Ee = 0 mV and Ei = -75 mV. Other synaptic noise parameter values were chosen to obtain an average membrane potential of about -65 mV with SD around 4 mV characteristic for in vivo states of cortical neurons (Destexhe and Paré 1999
; Paré et al. 1998
), and were ge0 = 12.1 nS, gi0 = 57.3 nS,
e = 12 nS,
i = 26.4 nS,
e = 2.73 ms, and
i = 10.49 ms.
Simulations of the point-conductance model and its comparison with more complex models are illustrated in Fig. 1. The point-conductance model (Fig. 1A) generates irregular subthreshold activity consistent with in vivo measurements (Destexhe et al. 2001
). It is characterized by a Lorentzian power spectrum (Fig. 1C, dashed lines), as well as by a symmetric (Gaussian) distribution of excitatory and inhibitory conductances (Fig. 1D, dashed lines), resulting in a nearly symmetric amplitude distribution of the membrane potential Vm (Fig. 1E, dashed lines).
Single-compartment model with individual noise sources
The second model consisted in a single-compartment membrane with a more realistic representation of synaptic inputs, which were modeled by a large number of individual synaptic conductances. In this case, the synaptic current Isyn(t) in Eq. 1 was described by
![]() | (4) |
-amino-3-hydroxy-5-methyl-4-isoxazolepropionic (AMPA) and
-aminobutyric acid (GABA) postsynaptic receptors (Destexhe et al. 1998
![]() | (5) |
{e,i} and
{e,i} are respectively forward and backward binding rate constants for excitation (index e) and inhibition (index i). When a spike occurred in the presynaptic compartment, a pulse of transmitter was triggered such that [T] = Tmax for a short time period tdur and [T] = 0 until the next release occurs. These kinetic models of synaptic currents were as described previously (Destexhe et al. 1998
exc and
inh for AMPA and GABAA synapses, respectively. The activation of N-methyl-D-aspartate (NMDA) receptors is minimal at the subthreshold levels investigated here, and were not included for simplicity.
The model was simulated numerically with passive properties as in the point-conductance model. Synaptic parameters were N = 4,472, M = 3,801, gAMPA = 1,200 pS, gGABA = 600 pS,
e = 1.1 x 106 M-1 s-1,
e = 670 s-1 for AMPA receptors,
i = 5 x 106 M-1 s-1,
i = 1 80 s-1 for GABAA receptors, Tmax = 1 mM, tdur = 1 ms,
exc = 2.16 Hz, and
inh = 2.4 Hz.
Simulations of this model are illustrated in Fig. 1B. The power spectra of the total excitatory and inhibitory conductances are approximately Lorentzian (Fig. 1C, gray), whereas their amplitude distributions take a nearly symmetric (Gaussian) shape (Fig. 1D, gray). Also the Vm amplitude distribution follows an approximately symmetric behavior (Fig. 1E, gray). It is to be noted that the point-conductance model captures these properties remarkably well (compare gray areas with dashed lines in Fig. 1, CE), thus suggesting that the Ornstein Uhlenbeck stochastic process yields a valid description of synaptic noise.
Detailed biophysical model
The third model consisted in a compartmental model of a neocortical layer VI pyramidal neuron obtained from morphological reconstructions of cells recorded in cat association cortex (Contreras et al. 1997
). The passive properties (see point-conductance model) were adjusted by matching the model to intracellular recordings obtained in the absence of synaptic activity (Destexhe and Paré 1999
). In some cases, voltage-dependent conductances were inserted in the soma, dendrites, and axon and were described by Hodgkin and Huxley (1952
) type models. The latter model included 2 voltage-dependent currents, a fast Na+ current INa, and a delayed-rectifier K+ current IKd, for action potential generation (Traub and Miles 1991
) with conductance densities of 8.4 and 7 mS/cm2 (Huguenard et al. 1988
; densities were 10 times higher in the axon), respectively. To account for the spike-frequency adaptation and afterhyperpolarization commonly observed in "regular-spiking" neurons, a slow voltage-dependent K+ current IM (muscarinic potassium current; Gutfreund et al. 1995
) with conductance densities of 0.35 mS/cm2 (soma and dendrites, no IM in axon) was added. In some simulations, models of cortical neurons with additional fast inactivating A-type K+ current IKA (model from Migliore et al. 1999
; conductance density from Bekkers 2000
), T-type (low threshold) Ca2+ current ICaT (model from Traub et al. 2003
; conductance density from Hamill et al. 1991
) and hyperpolarization-activated current Ih (model and nonuniform conductance density from Stuart and Spruston 1998
) were used.
To simulate synaptic inputs, pyramidal cells were divided into different regions (soma, perisomatic dendrites, main dendrites, axon initial segment) and the density of AMPA and GABAA synapses in each region was estimated from morphological studies (see DeFelipe and Fariñas 1992
; for kinetic parameters see single-compartment model with individual noise sources). The number of synapses per 100 µm2 of membrane were: 1020 (GABAA, soma and perisomatic dendrites), 4080 (GABAA, axon initial segment), 812 (GABAA, dendrites), and 5565 (AMPA, dendrites), leading to a total of N = 16,563 glutamatergic and M = 3,376 GABAergic synapses. Synaptic currents were simulated by kinetic models of AMPA and GABAA receptor types as described above, and synaptic background activity was simulated by random (Poisson-distributed) synaptic events at a mean rate of
exc = 1 Hz and
inh = 5.5 Hz for AMPA and GABAA synapses, respectively. This model was described in detail in a previous study (Destexhe and Paré, 1999
).
To estimate the conductances underlying synaptic activity, as well as their variances, we followed a procedure identical to that of a previous paper (Destexhe et al. 2001
). An "ideal" voltage clamp (without electrode series resistance) was simulated using a somatic electrode. The model was run twice at 2 different clamped voltages (-65 and -55 mV), and using the same random seed (so that the same random numbers were used at each clamp). The leak-subtracted currents obtained were then decomposed into excitatory and inhibitory conductances using the relation
![]() | (6) |
All simulations were performed using the NEURON simulation environment (Hines and Carnevale 1997
) and were run on PC-based workstations under the Linux operating system.
In vitro experiments
In vitro experiments were performed on 0.4-mm-thick coronal or sagittal slices from the lateral portions of the ferret occipital cortex including primary and secondary (areas 17, 18, and 19) visual cortical areas. Ferrets, 412 mo old (Marshall Europe, Lyon), were anesthetized with sodium pentobarbital (30 mg/kg). The slices were maintained in an interface-style recording chamber at 3536°C. Slices were prepared on a DSK microslicer (Ted Pella, Redding, CA) in a slice solution in which the NaCl was replaced with sucrose while maintaining an osmolarity of 307 mOsm. After transfer to the recording chamber, the slices were incubated in slice solution containing (in mM): NaCl, 124; KCl, 2.5; MgSO4, 2; NaHPO4, 1.25; CaCl2, 2; NaHCO3, 26; dextrose, 10, and was aerated with 95% O2-5% CO2 to a final pH of 7.4. After about 1 h, the slice solution was modified to contain 1 mM MgCl2, 1 or 1.2 mM CaCl2, and 3.5 mM KCl (Sanchez-Vives and McCormick 2000
). Intracellular recordings after 2 h of recovery were performed in deep layers (layers IV, V, and VI) on electrophysiologically identified regular spiking and intrinsically bursting cells. Electrodes for intracellular recordings were made on a Sutter Instruments P-87 micropipette puller from medium-walled glass (WPI, 1BF100) and beveled on a Sutter Instruments beveler (BV-10M). Micropipettes were filled with 1.2 to 2 M potassium acetate and had resistances of 80100 M
after beveling.
Ferret visual cortical slices spontaneously display recurrent periods of activity lasting 0.51.5 s, which are separated by periods of quiescence lasting 220 s (Sanchez-Vives and McCormick 2000
). In intracellular recordings, this active network activity manifests as a depolarized state ("up-state"). During the periods of quiescence ("down-state"), the membrane potential relaxes toward its resting value. To characterize synaptic noise, intracellular recordings in up- and down-states were collected at several different membrane potentials maintained by injection of steady currents through the recording micropipette (current-clamp).
Dynamic-clamp experiments
The dynamic-clamp technique (Robinson et al. 1993; Sharp et al. 1993
) was used to inject computer-generated conductances in real neurons. Dynamic-clamp experiments were run using the hybrid RT-NEURON environment (developed by G. Le Masson, INSERM U378, Université de Bordeaux), which is a modified version of NEURON (Hines and Carnevale 1997
) running under the Windows NT 4.0 operating system (Microsoft) on a PC equipped with a 1.4-GHz Pentium IV processor. NEURON was augmented with the capacity of simulating neuronal models in real time, synchronized with the intracellular recording. To achieve real-time simulations as well as data transfer to the PC for further analysis, we used a PCI DSP board (Innovative Integration, Simi Valley, CA) with 4 analog/digital (inputs) and 4 digital/analog (outputs) 16 bits converters. The DSP board constraints calculations of the models and data transfer process to be made with a high priority level by the PC processor. The DSP board allows input (e.g., the membrane potential of the real cell incorporated in the equations of the models) and output signals (the synaptic current to be injected into the cell) to be processed at regular intervals (time resolution = 0.1 ms). A custom interface was used to connect the digital and analog inputs/outputs signals of the DSP board with the intracellular amplifier (Axoclamp 2B, Axon Instruments) and the data acquisition systems (PC-based acquisition software ELPHY, developed by G. Sadoc, CNRS Gif-sur-Yvette, ANVAR, and Biologic). The dynamic-clamp protocol was used to insert the fluctuating conductances underlying synaptic noise in cortical neurons using the point-conductance model, similar to a previous study (Destexhe et al. 2001
). A critical feature for dynamic clamp and for the present method is the accuracy of the absolute membrane voltage measure. A reliable method is to monitor and adjust manually the Vm offset during the course of the recording according to the known statistical value of the onset of action potentials in a given cell type (e.g., -55 mV for ferret pyramidal cells; Shu et al. 2003b
). For this purpose, action potentials are triggered by square depolarizing pulses of current injected through the micropipette.
Data acquisition and analysis
Voltage traces from numerical simulations and experimental recordings were analyzed with respect to both their statistical properties and amplitude distribution
(V). In models, simulations were run using either passive models or models with active currents responsible for spike generation and adaptation (see above). In experiments, spontaneous up-states were collected using custom data acquisition software (ELPHY). In all cases, the data acquisition rate was 100 kHz (numerical simulations) or 20 kHz (experiments). To obtain subthreshold Vm distributions, steady hyperpolarizing current was used such that the average Vm in up-states was between -75 and -65 mV. The remaining action potentials, if present, were cut using a time window of 10 ms centered around the spike (taking advantage of the fact that signals need not to be contiguous to calculate amplitude distributions).
Vm distributions were calculated using bin sizes of 0.2 mV for traces from both simulations and experiments. The distributions obtained were fitted using a Gaussian template function (e.g., Eq. A6 in the APPENDIX), thereby providing directly the values for the average Vm,
, and its SD,
V. These estimates were also checked with standard statistical analysis tools for discrete data sets (Press et al. 1993
).
To calculate these values from the analytic expressions of
(V), which usually do not allow explicit integration, we integrated
(V) numerically, using
![]() | (7) |
![]() | (8) |
Finally, the effective membrane area (a) and the leak conductance density (gL) can be estimated from experimental data by using injection of hyperpolarizing current pulses during periods of quiescent activity, yielding estimates of the membrane time constant (
m) and of the resting input resistance (Rin). gL and a can be estimated using the following relations
![]() |
| RESULTS |
|---|
|
|
|---|
The VmD method: estimating synaptic conductances from membrane potential distributions
We consider the Vm probability density function
(V, t) of the point-conductance model defined in Eqs. 1, 2, 3.
(V, t) describes the probability density that the membrane potential Vm takes the value V at time t. The time evolution of this probability density function is given by the FokkerPlanck equation (Risken 1984
; see APPENDIX), which for the point-conductance model yields the following steady-state solution (Rudolph and Destexhe 2003b
)
![]() | (9) |
This analytic expression for the Vm distribution was derived and analyzed in detail in a previous study (Rudolph and Destexhe 2003b
). Here we focus on possible applications of this analytic approach to analyze subthreshold neuronal activity from current-clamp recordings. The general idea is to fit analytic expressions of the Vm distribution to distributions obtained experimentally, thereby providing estimates of the underlying conductance parameters, which characterize network activity.
Although this estimate could in principle be obtained by fitting Eq. 9 to experimentally measured Vm distributions, in practice, this approach poses a number of problems. The main obstacle is the highly nonlinear dependency of the the Vm distribution on its parameters (Eq. 9). In general, fitting a highly nonlinear function of many parameters to experimental data results in local minima that may lead to spurious estimates (Press et al. 1993
). To circumvent this difficulty, we need to simplify Eq. 9. Here, we can take advantage of the fact that the Vm distribution is only weakly asymmetric in V, especially in the range of Vm values typical of in vivo activity (-70 to -50 mV; see detailed analysis in Rudolph and Destexhe 2003b
). Furthermore, a very convenient symmetric approximation of Eq. 9 can be obtained and takes the form of a Gaussian distribution
![]() | (10) |
is the average Vm and
V is the standard deviation of the Vm. This Gaussian approximation can be obtained formally from Eq. 9 by second-order Taylor expansion around its peak value (see details in the APPENDIX). As we will see below, this expression provides an excellent approximation of the Vm distributions obtained from models and experiments.
The advantage of using a simplified expression such as Eq. 10 is 2-fold. First, one can obtain an expression of the quantities
and
V (very easy to measure in experiments) as a function of the synaptic conductance parameters (see Eqs. A5 and A7 in the APPENDIX), which allows physical interpretation of these quantities. For example, it can be seen that
is mostly determined by the static components of the synaptic conductances (ge0 and gi0), whereas
V has a more complex dependency on synaptic noise parameters. It depends on both ge0 and gi0, as well as on
e and
i.
The second and main advantage is that these expressions are mathematically simple enough to enable inverting them, which may lead to expressions of the synaptic noise parameters as a function of the Vm measurements,
and
V. The stochastic passive membrane equation, Eq. 1, is characterized by 6 parameters describing excitatory and inhibitory conductance noise (ge0, gi0,
e,
i,
e,
i). Two of these parameters, the noise time constants
e and
i, are related to the decay time of synaptic currents and thus the kinetics of synaptic transmission. Therefore, these parameters are expected to show little variations from cell to cell, and can be fixed using power spectra of synaptic conductances deduced from voltage-clamp recordings (see Destexhe et al. 2001
). In contrast, the remaining 4 parameters, the means (ge0, gi0) and SDs (
e,
i) of excitatory and inhibitory synaptic conductances, depend on the synaptic inputs converging to the cell as well as the actual network state. Thus these parameters are expected to vary from one situation to the other (e.g., between different network states), as well as from cell to cell (e.g., depending on the connectivity of that particular cell within the network), and should therefore be estimated for each case.
To extract the 4 conductance parameters (ge0, gi0,
e,
i) from the membrane probability distribution, Eq. 10 is, however, insufficient because it is characterized by only 2 parameters (
,
V). To solve this problem, one possibility is to consider 2 Vm distributions obtained at 2 different constant levels of injected current Iext1 and Iext2 (2 current-clamps protocol). In this case, expressing these 2 Vm distributions as Eq. 10 leads to 2 values for mean Vm,
1 and
2, as well as 2 values for the Vm SD,
V1 and
V2. If both distributions are obtained during the same network state, they can be expressed (using Eqs. A5 and A7 in the APPENDIX) as a function of the same 4 parameters (ge0, gi0,
e,
i). In this case, one obtains
![]() | (11) |
![]() | (12) |
These relations enable us to estimate global characteristic of network activity, such as mean excitatory (ge0) and inhibitory (gi0) synaptic conductances, as well as their respective variances (
2e,
2i), from the sole knowledge of the Vm distributions obtained at 2 different levels of injected current. This procedure, which we refer to below as the "VmD method," is illustrated in Fig. 2 and constitutes the core of the analysis explored in this paper.
|
3) can be used as consistency conditions for validating the obtained estimates. However, in what follows we restrict discussion to the 2 current-clamps protocol. Test of the approach using computational models
We now turn to computational models of increasing levels of complexity to test the conductance estimates provided by Eqs. 11 and 12. First, we used the point-conductance model to check for the validity of the expressions obtained. Because of the equivalence of the underlying equations (Eqs. 1, 2, and 3), here the closest correspondence between estimated and actual (i.e., calculated numerically) conductance parameters is expected.
Figure 3 illustrates the procedure applied to the Vm activity of that model (Fig. 3A). Two different values of steady current injection (Iext1 and Iext2) yield 2 Vm distributions (Fig. 3B, gray). These distributions were fitted with a Gaussian function to obtain the means and SDs of the membrane potential at both current levels. Incorporating the values
1,
2,
V1, and
V2 into Eqs. 11 and 12 yields values for the mean and SD of the synaptic noise, g{e,i}0 and
{e,i}, respectively (Fig. 3C, solid line, and Fig. 3D). These estimates were then used to reconstruct the full analytic expression of the Vm distribution using Eq. 9, which was plotted in Fig. 3B (solid lines). There was a very close match between the analytic estimates of
(V) and numerical simulations (Fig. 3B, compare gray areas with solid lines). This demonstrates not just that Gaussian distributions are an excellent approximation for the membrane potential distribution in the presence of synaptic noise, but also that the proposed method yields an excellent characterization of the synaptic noise and thus subthreshold neuronal activity. This can also be seen by comparing the reconstructed conductance distributions (Fig. 3C, solid lines) with the actual conductances recorded during the numerical simulation (Fig. 3C, gray). Distributions deduced from the estimated parameters were in excellent agreement with those of the numerical simulations. Thus, this first set of simulations shows that, at least for the point-conductance model, the proposed approach provides a method that allows an accurate estimate of the mean and the variance of synaptic conductances from the sole knowledge of the (subthreshold) membrane potential activity of the cell.
|
|
(V) (Fig. 5B, left panel, solid lines), which captured very well the shape of the Vm distributions obtained numerically, although small deviations are visible at the hyperpolarized and depolarized tail of the distributions. The reconstructed conductance distributions (Fig. 5C, solid lines) were also in excellent agreement with the conductance distributions obtained in this model using an ideal voltage clamp at the soma (Fig. 5C, gray; see method in Destexhe et al. 2001
|
i (Fig. 5D, right panel), and yielded Vm distributions that were slightly broader. However, these errors and deviations remained relatively small and the method still provided a good estimate of synaptic conductances, similar to or better than the one provided by ideal voltage clamp (Fig. 6).
|
The method was further tested against real network activity. We used the recurrent activity ("up-states") occurring spontaneously in ferret neocortical slices (see METHODS). Intracellularly, this activity consists in a depolarized Vm and relatively large-amplitude Vm fluctuations (Fig. 7), as described previously (Sanchez-Vives and McCormick 2000
). To test the method, we applied an on-line protocol (Fig. 7A), consisting of estimating synaptic conductances from "natural" up-states (top traces) and compared them to "artificial" up-states obtained by dynamic-clamp injection of the estimated conductances in the same neuron (bottom traces). As above, the estimates (Fig. 7A, solid distributions) were obtained by computing the Vm distributions at 2 different current levels (Fig. 7A, top, gray distributions) and fit them using the Gaussian approximation (Eqs. 11 and 12). For the particular neuron shown in Fig. 7A, the estimated inhibitory synaptic conductance parameters were approximately twice as large as those for excitation (see bottom bar plots). These parameters were then used to generate conductance waveforms according to the stochastic process of Eq. 3 ("Model of synaptic noise" in Fig. 7A). These conductance waveforms were then reinjected in the same neuron ("Dynamic-clamp" in Fig. 7A), leading to re-created up-states, which are compared to natural up-states. In several cells tested (n = 4), the re-created states had properties (average Vm, Vm fluctuations, firing behavior) similar to those of the natural up-states (see example in Fig. 7B).
|
e, and
i were then used to generate stochastic conductance waveforms (Fig. 8A, bottom traces). Injection of these conductance waveforms during quiescent states into the same cell led to artificial up-states, in which Vm distribution was in excellent agreement with the natural up-states [see
(V) graph in Fig. 8A]. This dynamic-clamp protocol shows that the network activity, as predicted by the Vm distribution method, is perfectly consistent with the natural network activity.
|
e, and
i parameters. The artificial up-states obtained were then analyzed using the VmD decomposition method. This procedure led to estimated values in excellent agreement with the injected values (compare light and dark gray in bar plot of Fig. 8B). Thus, the method provides an acceptable estimate of the injected conductances from the sole knowledge of the Vm activity. | DISCUSSION |
|---|
|
|
|---|
Starting from a purely theoretical approach, the mathematical description of the stochastic variations of Vm, we derived expressions to relate Vm measurements to global synaptic conductance parameters, such as the mean excitatory (ge0) and inhibitory (gi0) conductances, as well as their respective variances (
e,
i). The mean synaptic conductances are related to the mean rate of afferent neurons, whereas the variances of these conductances are related to the level of correlation between presynaptic activities (Destexhe et al. 2001
). So far, experimental measurements have concentrated on estimating the mean conductances (Anderson et al. 2000
; Borg-Graham 1998; Hirsch et al. 1998
; Shu et al. 2003a
), which is equivalent to estimating the mean level of afferent activity. Measuring conductance variances can give estimates of the mean level of correlation within afferent activity (Destexhe et al. 2001
). However, such estimates were never provided so far, presumably because of the technical difficulty of measuring conductance variances in vivo, which presently requires voltage-clamp methods.
The present Vm distribution method provides such estimates based on current-clamp recordings. It relies on quantities (mean and variance of the Vm), which are relatively easy to measure experimentally. Conductances are usually best estimated from voltage-clamp recordings (Borg-Graham et al. 1998
), although methods from current-clamp recordings have been used as well (Anderson et al. 2000
; Hirsch et al. 1998
). The method proposed here relies on standard current-clamp protocols, in which spontaneous activity is recorded with steady current injection, which corresponds to the most current configuration used for performing intracellular recordings in vivo.
We have shown that the method can provide relatively good estimates of global synaptic conductances, even in the case of complex models, including the dendritic morphology and active channels in dendrites (Fig. 5). In the latter case, the method provides measurements of global conductances and their variances with an accuracy comparable to that of an "ideal" voltage clamp. However, it must be noted that the method we used here to estimate conductance variances from voltage clamp required running the models twice with the same seed for random numbers. On the contrary, the proposed VmD method provides such an estimate without requirements of this type.
On the negative side, the method proposed here to estimate conductance variances relies on a series of parameters. First, there must be an estimation of the "effective" leak conductance (i.e., the nonsynaptic conductance) and membrane area a. These values can be obtained in vitro by measuring the input resistance and time constant in quiescent periods (see METHODS). Second, voltage-dependent currents in soma and dendrites may distort the Vm distribution and cause errors in the estimate, attributed to either the presence of regenerative dendritic spikes or the activation of voltage-dependent membrane conductances. The latter applies to all currents that are active in the subthreshold Vm range, such as the hyperpolarization-activated current Ih. Slow K+ currents may also be activated in the subthreshold range, although in our simulations (Fig. 5) there were slow K+ currents, but their presence did not seem to have strong effects on the estimates. Various K+ currents (such as those underlying spike afterhyperpolarization or the A-type K+ current IKA), various Ca2+ currents (such as the low-threshold T-current ICaT), or Ih may also significantly distort the Vm distribution (see Fig. 6), but the distorting effect of these currents can easily be avoided (see METHODS). Moreover, as our numerical simulations showed, despite a significant impact of these active currents, the estimates obtained with the VmD method were closer to the actual synaptic conductances compared to estimates with ideal voltage clamp. However, to minimize voltage-dependent effects, the best is to identify a linear region of the IV curve of the neuron, and perform the measurements in that region. The excellent agreement obtained here using experimental recordings (Fig. 8) also suggests that these contaminations are minimal in the voltage range considered. Furthermore, using Gaussian fits of the Vm distributions effectively suppresses the effect of dendritic spikes arriving at the site of the recording and, thus, improves the applicability of the method. Third, the presented VmD method restricts, so far, only to glutamatergic and GABAA receptors. The impact of other receptor types, such as GABAB and NMDA, remains to be investigated and neglecting them might contribute to errors in the conductance estimates. Moreover, the knowledge of the reversal potential for GABAergic or glutamatergic synapses is crucial and using wrong values of reversals will result in estimation errors. Ideally, the reversal potentials should be measured for the same preparation in which the analysis is made. Finally, drifts in the membrane potential (e.g., arising from the experimental setup or from unstability of the recording) constitute another source of error. The proposed method requires a stationary recording, which was the case for all cells shown here.
Another potential source of error comes from the spatial aspect of synaptic noise. Here, synaptic inputs received distally will contribute less to the somatic response compared to those close to the soma. This will, in general, result in an underestimation of the total synaptic conductances and their variation. Moreover, a nonuniform distribution of synaptic conductances, such as the higher density of GABAergic synapses in the proximal region of cortical neurons, or the distance-dependent scaling of quantal conductances or receptor number, will bias the estimates for excitatory and inhibitory conductances. However, our simulations, which took the spatial distribution of (uniform) synaptic channels and the asymmetry in the distribution of glutamatergic and GABAergic synapses into account, showed only minimal deviations from the corresponding voltage-clamp estimates of the excitatory and inhibitory synaptic conductances. In addition, our method yields estimates for the total synaptic conductances that determine the cellular dynamics at the site of the recording, a quantity that does not depend on a specific assumption of the distribution of synaptic channels within the dendritic tree.
This approach is also applicable to in vivo intracellular experiments. In this case, the mean and variance of synaptic conductances could be estimated across different states of the network. The difficulty, however, would be to estimate the resting parameters (gL, a), which are not easy to deduce in vivo. However, if quiescent states can be obtained either pharmacologically (Paré et al. 1998
) or spontaneously ("down-states"), then estimates of those parameters can be obtained. Alternatively, it is always possible to use the present approach with minor modifications to estimate relative changes of conductances or conductance variances between different states of the network. In particular, measuring changes in conductance variances should allow us to measure changes in correlation in network activity. Such measurements have not been obtained yet, but s