J Neurophysiol (April 30, 2008). doi:10.1152/jn.01114.2007
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
100/1/92    most recent
01114.2007v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by Middlebrooks, J. C
PubMed
Right arrow PubMed Citation
Right arrow Articles by Middlebrooks, J. C
Submitted on October 8, 2007
Accepted on April 25, 2008

Cochlear-Implant Pulse Rate and Narrow Electrode Configuration Impair Transmission of Temporal Information to the Auditory Cortex

John C Middlebrooks1*

1 Kresge Hearing Research Institute, Ann Arbor, Michigan, United States

* To whom correspondence should be addressed. E-mail: jmidd{at}umich.edu.

In the most commonly used cochlear prosthesis systems, temporal features of sound are signaled by amplitude modulation of constant-rate pulse trains. Several convincing arguments predict that speech reception should be optimized by use of pulse rates higher than ~2000 pulses/s (pps) and by use of intra-cochlear electrode configurations that produce restricted current spread (e.g., bipolar rather than monopolar configurations). Neither of those predictions has been borne out in consistent improvements in speech reception. Neurons in the auditory cortex of anesthetized guinea pigs phase lock to the envelope of sine-modulated electric pulse trains presented through a cochlear implant. The present study used that animal model to quantify the effects of carrier pulse rate, electrode configuration, current level, and modulator wave shape on transmission of temporal information from a cochlear implant to the auditory cortex. Modulation sensitivity was computed using a signal-detection analysis of cortical phase-locking vector strengths. Increasing carrier pulse rate in 1-octave steps from 254 pps to 4069 pps resulted in systematic decreases in sensitivity. Comparison of sine- versus square-wave modulator waveforms demonstrated that some, but not all, of the loss of modulation sensitivity at high pulse rates was a result of the decreasing size of pulse-to-pulse current steps at the higher rates. Use of a narrow bipolar electrode configuration produced a marked decrease in modulation sensitivity compared to the monopolar configuration. Results from this animal model suggest explanations for the failure of high pulse rates and/or bipolar electrode configurations to produce hoped-for improvements in speech reception.




This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
J. C. Middlebrooks
Auditory Cortex Phase Locking to Amplitude-Modulated Cochlear Implant Pulse Trains